Cavity Weep™ Installation
Self-Spaced Brick Weeps
CV 5010
Cavity Weep Installation
- Place Cavity WeepTM on flashing with continuous belt centered in the cavity and legs extending out from face of wall about 1” to 1.5”
- Place bed joint of mortar on Cavity WeepTM and lay masonry units
- Tool joints and lightly score legs at face of wall; crack off by pushing downward while mortar is still plastic
- Finish tool joint and brush