Sure Cavity™ - 10mm Sure Cavity™ - Moisture Diverter ™
SC 5016, SC 5032 - SCMM 2516, SCMM 2532 - DS 2858
Sure Cavity™
Works because
- it separates cementitious materials
from the moisture resisitant system on the structural back-up walls
while creating a drainage
system that allows moisture to
travel down and out of
walls.
- it prevents bridging.
- the spunbond polypropylene fabric
holds cementitious materials awau from vertical moisture channels and weeps.
- it is easy to install.
Sure Cavity™ Product Dimensions
- Sure Cavity™ SC 5016 is 15 3/4" high, 3/16" thick, in 50' long rolls, covering 66 sq. ft.
- Sure Cavity™ SC 5032 is 31 1/2" high, 3/16" thick, in 50' long rolls, covering 132 sq. ft.
- Sure Cavity™ SCMM 2516 is 15 3/4" high, 10mm thick, 25' long rolls, covering 33 sq. ft.
- Sure Cavity™ SCMM 2532 is 31 1/2" high, 10mm thick, 25' long rolls, covering 66 sq. ft
Installation
- Position Sure Cavity™ with the spunbond fabric facing to weather with 4" fabric skirt wrapped back under bottom on first course.
- Spunbond fabric 4" skirt should overlap the top of the lower course of Sure Cavity™.
- Construction paper, Sure Cavity™ and metal lath to extend down over top of foundation wall a minimum of 2".
Product Info Sheet: | SC 5016 | SC 5032 | SCMM 2516 | SCMM 2532 |
Moisture Diverter™
Works because
- It stops moisture and diverts it to either side and away from moisture-sensitive wall details.
- It answers a critical need above wall openings
Moisture Diverter™ Product Dimensions
- Moisture Diverter™ DS 2858 is a 28 Ga. 2 1/2" wide galvanized metal strip
- It is V-shaped 65 degree open angle channel
- It has a Front Leg of 5/8", a Back Leg of 1 7/8", and is 4' long
Installation
- Position Moisture Diverter™ above wall openings (window, door, etc.) immediately above, but not in contact with, mounting flanges or flashing systems.
- Make Moisture Diverter™ watertight against moisture resistant coatings on masonry or poured concrete walls.
- Install flashing and overlap construction paper shingle-fashion on framed wall.
- Install Moisture Diverter™ with ¼ inch to 1” slope-to-drain.
- Moisture Diverter™ must extend a minimum of 4” past window mounting flange or window trim boards on both sides of window.
- View Animation for step-by-step installation instructions.
Product Info Sheet: | DS 2858 |